Neurovascular Operation Training Model-Type A

This circle of willis model is mainly made of high transparent soft silica gel, which is used for surgical training related to intracranial artery interventional diagnosis and treatment, performance test and function demonstration of surgical instruments. The surgical instruments involved include intracranial vascular interventional guide wire, catheter, stent, spring coil, thrombectomy device, thrombus filter and other instruments.

Neurovascular Operation Training Model-Type A PDF

Description

Neurovascular Operation Training Model-Type A adalah simulator sirkulus Willisi yang komprehensif. Mencakup arteri serebral (anterior, posterior, middle), arteri basilar, hingga akses vaskular utama dari arteri radialis dan femoralis.

Didesain untuk pelatihan prosedur intervensi intrakranial seperti *coiling* aneurisma, trombektomi stroke iskemik, dan pemasangan stent. Transparansi tinggi memudahkan visualisasi pergerakan *guidewire* dan kateter di dalam pembuluh darah.

Spesifikasi Teknis

Fitur
  • It includes cerebral artery vessels such as the anterior posterior middle artery, basilar artery, Willis ring, etc. with aneurysms and narrowed segments, as well as the main blood vessels and branches of nerve intervention surgical pathways such as the left and right vertebral arteries, left and right common carotid arteries, thoracic aorta, iliac artery, and femoral artery.

  • High transparency material with excellent visualization effect: The main body is made of food grade high transparency soft silicone, which can clearly observe the movement status of vascular instruments.

  • Optimization design based on real human CT data, 1:1 restoration of intracranial and systemic arterial lumen dimensions (including key blood vessels such as the middle cerebral artery, internal carotid artery, aortic arch, etc.).

  • It can adapt to the testing and evaluation of interventional instruments such as guide tubes, guide wires, balloon dilation stents, and can also carry out surgical training such as angiography and balloon dilation; Support customized aneurysm and stenosis lesions at different locations to meet diverse testing and training needs.

  • Special instrument insertion ports are set up in the radial artery, femoral artery, and subclavian artery to fit the clinical interventional surgical approach; mark

PN PLSJXG001A 

Main Material

Highly transparent soft silica gel, hardness: 30A

Product SizeModel length: 104 cm 

Model width: 49 cm 

Model height: 19 cm 

Lead Time15 days
OriginShanghai, China

Drawing of Neurovascular Operation Training Model-Type A

Frequently Asked Questions

Q: Apakah ada aneurisma?

A: Ya, model ini dilengkapi dengan simulasi aneurisma dan segmen penyempitan (stenosis) pada lokasi yang anatomis.

Q: Apakah bisa dikustomisasi?

A: Modul aneurisma dan lesi stenosis dapat dikustomisasi letaknya sesuai kebutuhan pelatihan spesifik.

Q: Bagaimana cara membersihkannya?

A: Cukup dibilas dengan air bersih. Sistem ini mudah dirawat dan portabel.