Neurovascular Operation Training Model-Type B

This product is mainly made of high transparent soft silica gel, which is used for surgical training related to intracranial artery interventional diagnosis and treatment, performance test and function demonstration of surgical instruments. The surgical instruments involved include intracranial vascular interventional guide wire, catheter, stent, spring coil, thrombectomy device, thrombus filter and other instruments.

Neurovascular Operation Training Model-Type B PDF

Description

Neurovascular Operation Training Model-Type B menawarkan kompleksitas anatomi tingkat lanjut dengan tambahan fitur tortuositas. Memiliki dua kelengkungan 180 derajat dan dua kelengkungan 360 derajat pada segmen sifon arteri karotis interna.

Sangat cocok untuk menguji kemampuan manuver (*trackability* dan *pushability*) perangkat intervensi pada anatomi yang menantang. Mencakup akses lengkap dari arteri radialis, femoralis, dan subklavia.

Spesifikasi Teknis

Fitur
  • It includes cerebral artery vessels such as the anterior posterior middle artery, basilar artery, Willis ring, etc. with aneurysms and narrowed segments, as well as the main blood vessels and branches of nerve intervention surgical pathways such as the left and right vertebral arteries, left and right common carotid arteries, thoracic aorta, iliac artery, and femoral artery. Two 180 degree bends and two 360 degree bends have been added to the siphon segment of the internal carotid artery.

  • Support the testing and performance evaluation of vascular intervention devices such as guide catheters, guide wires, balloon dilation stents, and adapt to the compatibility and functional verification of various intervention devices.

  • Simulation training for vascular intervention surgeries such as angiography and balloon dilation can be conducted to help operators become familiar with the surgical process and instrument operation skills.

  • Support customized modules for aneurysms and vascular stenosis lesions at different locations according to needs, meeting diverse testing, training, and display scenario requirements.

  • Special guide wires and catheter insertion ports are set up in the radial artery, femoral artery, and subclavian artery to accurately simulate the real instrument approach of clinical neurovascular intervention surgery and improve the fit of the operation simulation.

PNPLSJXG00B

Main Material

Highly transparent soft silica gel, hardness: 30A

Product SizeModel length: 104 cm 

Model width: 49 cm 

Model height: 19 cm 

Lead Time15 days
OriginShanghai, China

Drawing of Neurovascular Operation Training Model-Type B

Frequently Asked Questions

Q: Apa bedanya dengan Tipe A?

A: Tipe B memiliki fokus pada anatomi sifon karotis yang lebih berliku (*tortuous*) untuk simulasi akses sulit.

Q: Apakah bisa untuk latihan trombektomi?

A: Bisa, mendukung simulasi pengambilan bekuan darah (trombektomi mekanis) dengan *clot retriever*.

Q: Materialnya apa?

A: Silikon transparan 30A yang mereplikasi gesekan dan elastisitas dinding pembuluh darah manusia.